1 CH CANFD, 6 CH LIN to USB – TC1026
SKU : TC1026
TC1026 is a multi-channel CANFD and LIN bus interface device launched by TOSUN, CANFD bus rate support up to 8M bps, LIN support rate 0 ~ 20 Kbps, the product uses high-speed USB2.0 interface and PC connection, Windows and Linux system drive design makes the device have excellent system compatibility.
$1,300.00
Datasheet
UserManual
Related Products
Related products
TC1026 Functions and parameters
The LIN channel require external power supply, maximum voltage is 24V.
–
With powerful TSMaster software, support loading DBC and ARXML database files, can easily monitor, analyze, simulate CAN FD / LIN bus data, can also support UDS diagnosis, ECU brush, CCP / XCP calibration and other functions.
Can be used for the secondary development API of Windows and Linux, can support various development environments, such as C + +, C #, LabView, Python, etc., convenient integration into various test systems, efficient and easy to use.
- us (microsecond) level hardware message timestamp to meet higher order requirements
- High-speed USB2.0 interface, Windows, Linux system drive-free design, with excellent system compatibility
- CAN channel DC2500V sequestration
- Automotive grade design, support LDF, dbc file, a2l file, blf file, asc file, arxml file
- CAN channel port rate 125 Kbps- -1Mbps tunable
- The LIN bus master and slave nodes can be software configured
- Support b lf, asc format data recording and offline / online playback
- UDS diagnosis and CCP and XCP calibration can be supported
- Support for the UDS-based Flash Bootloader
- LIN bus UDS based diagnosis can be supported
- Support for information security testing
- Support Windows, Linux system secondary development interface
- Built-in 120 euro terminal resistance can be used in software configuration
- Loadable TSMaster software all charge license
![TC1026/TC1026P_LIN, TC1034, TLog1002_LIN, TLog1004 pin img](https://tosunai.us/wp-content/uploads/2023/12/TC1026_LIN-TC1034_FR-TLog1002_CF-1.webp)
LIN 1/2/3
![TC1026/TC1026P_LIN, TC1034, TLog1002_LIN, TLog1004 pin img](https://tosunai.us/wp-content/uploads/2023/12/TC1026_LIN-TC1034_FR-TLog1002_CF-1.webp)
LIN 4/5/6
![TC1001, TC1011, TC1026/TC1026P_CANFD PIN IMG](https://tosunai.us/wp-content/uploads/2023/12/TC1001-TC1011-TC1026_CANFD.webp)
Typical applications
- Multi-channel CAN FD / CAN / LIN bus data acquisition
- Domain Controller Test
- Various automated test systems
Additional information
channel | 1 * CAN FD / 6 x*LIN |
---|---|
PC terminal interface | High-speed of USB2.0 |
The CAN / LIN terminal interface | DB9 |
drive | Windows, Linux system free drive design, with excellent system compatibility |
cache | Hardware cache, each channel sends buffer support to 1000 frames CAN / CANFD |
CAN | Support CAN2.0A, B protocol, comply with ISO11898-1 specification, port rate 125 Kbps- -1Mbps |
CAN FD | Support for ISO and non-ISO standard CAN FD, port rate 125 Kbps–8Mbps |
LIN | Support LIN 1.3 and 2.0, Porter rate 0- -20 Kbps |
dispatch list | Support LDF files and run the schedule, or you can configure the schedule yourself |
Time stamp accuracy | 1us, the hardware message timestamp, to meet the high-order requirements |
terminal resistance | Built-in 120 euro terminal resistance can be used in software configuration |
Send a message per second * | Maximum of 20,000 frames / s |
Receipt of message messages per second * | Maximum of 20,000 frames / s |
* | Single-channel 1Mbps, 0-byte data domain case |
insulate | CAN channel DC 2500V isolation, electrostatic grade contact discharge ±8KV |
supply electricity | USB power supply, and LIN communication needs external power supply |
Case material | aluminium product |
size | 100mm*80mm*30mm |
working temperature | -40℃~80℃ |
Working humidity | 10% ~ 90% (no condensation) |
work environment | Stay away from the corrosive gases |
During operation, make sure to correctly connect the power lines and avoid frequent plugging and unplugging.