4 CAN FD, 2 LIN to USB interface – TC1016
SKU : TC1016
TC1016 is a multi channel CAN FD and LIN bus interface device introduced by TOSUN. It supports a maximum CAN FD bus speed of 8Mbps and LIN speeds ranging from 0 to 20Kbps.
$1,300.00
Datasheet
UserManual
Related Products
Related products
TC1016 Functions and parameters
The product connects to a PC via a high-speed USB 2.0 interface, designed with driverless compatibility for Windows and Linux systems, ensuring system compatibility.
Paired with the robust TSMaster software, it supports loading DBC, LDF, ARXML database files, facilitating convenient monitoring, analysis, and simulation of CAN FD/LIN bus data. Additionally, it supports functionalities such as UDS diagnostics, ECU flashing, CCP/XCP calibration, among others.
This device provides secondary development APIs for Windows and Linux systems, supporting various development environments such as C++, C#, LabView, Python, etc. This flexibility allows for easy integration into diverse testing systems, ensuring efficiency and user-friendliness.
- Microsecond (μs) level hardware message timestamping, meeting high-level requirements
- High-speed USB 2.0 interface, designed for compatibility with Windows and Linux systems, driverless setup
- CAN channel isolation up to DC2500V
- Automotive-grade design, supporting LDF, dbc, a2l, blf, asc, and arxml file formats
- Adjustable CAN bus baud rate from 125Kbps to 8Mbps
- LIN bus master and slave nodes can be configuredvia softwareSupport for recording data in blf and asc formats, enablingoffline/online playback
- Supports UDS diagnostics and CCP/XCP calibration
- Supports UDS-based Flash Bootloader
- Supports LIN bus-based UDS diagnostics
- Supports information security testing
- Secondary development interfaces for Windows and Linux systems
- Built-in 120-ohm terminal resistor, software configurable
- Supports all paid licenses for TSMaster software
LIN 1/2
-
PIN2 GND
-
PIN3 GND1
-
PIN6 LIN2
-
PIN7 VBAT_LIN2
-
PIN8 LIN1
-
PIN9 VBAT_LIN1
CAN FD 1/3
-
PIN2 CANFD1_Low
-
PIN3 CANFD_GND
-
PIN4 CANFD3_Low
-
PIN5 CANFD_Shield
-
PIN7 CANFD1_High
-
PIN8 CANFD3_High
CAN FD 2/4
-
PIN2 CANFD2_Low
-
PIN3 CANFD_GND
-
PIN4 CANFD4_Low
-
PIN5 CANFD_Shield
-
PIN7 CANFD2_High
-
PIN8 CANFD4_High
Typical applications
- Whole vehicle multi-channel CAN FD/CAN/LIN bus data acquisition
- Domain controller testing
- Various automated testing systems
- ECU flashing
Specification
channel | 4 x CAN FD 2 x LIN |
---|---|
PC End | High-speed USB 2.0 interface |
CAN/LIN End | DB9 interface |
Driver | Driver-free design for Windows and Linux systems, ensuring system compatibility |
Buffer | Each channel supports a transmit buffer of up to 1000 CAN frames |
CAN | Supports CAN 2.0A, B protocols, compliant with ISO11898-1 standard, with baud rate 125Kbps-1Mbps |
CAN FD | Supports CAN FD that complies with both ISO and non-ISO standards, with baud rates from 125Kbps to 8Mbps |
LIN | Supports LIN1.3 and 2.0, baud rate from 0 to 20Kbps |
Schedule Table | Supports LDF files and running scheduling tables, or configuring scheduling tables independently |
Timestamp | 1μs hardware message timestamp |
Terminal Resistor | Built-in 120-ohm terminal resistor, software-configurable |
Messages Sent per Second* | Maximum of 20,000 frames/second |
Messages Received per Second* | Maximum of 20,000 frames/second |
* | Single channel at 1 Mbps with a 0-byte data field |
Isolation | CAN channel isolation up to DC2500V, electrostatic discharge level ±8KV |
Power Supply | USB-powered, external power supply required for LIN communication |
Casing Material | Aluminum |
Dimensions | 100mm x 80mm x 30mm |
Operating Temperature | -40℃~80℃ |
Operating Humidity | 10% to 90% (non-condensing) |
Operating Environment | Keep away from corrosive gases |
During operation, make sure to correctly connect the power lines and avoid frequent plugging and unplugging.